Sign In | Join Free | My himfr.com
Home > Transformer Tester >

350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector

    Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers
     
    Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers
    • Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers
    • Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers
    • Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers
    • Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers
    • Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers
    • Buy cheap 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector from wholesalers

    350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector

    Ask Lasest Price
    Certification : CE, ISO
    Brand Name : XZH TEST
    Model Number : XHSP1700
    Payment Terms : T/T
    Supply Ability : 1000pieces/Year
    Delivery Time : 5-8 days
    • Product Details
    • Company Profile

    350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector

    Transformer oil gas tester/gas chromatograph analyzer

    Main technical datas
    • operating display: 5.7 inch periodic lattice Chinesize color liquid crystal (can be equipped with touch screen)
    • temperature control area: 6 ways • temperature: room temperature above 5 ºC ~ 400 ºC, incremental:1 ºC, accuracy :± 0.1 ºC
    • temperature-programmed order: 16 order
    • Temperature program rate: 0.1 ~ 39 ºC /min (common type); 0.1 ~ 80 ºC /min (high speed)
    • the gas control: optional pressure flow control mode of the mechanical valve control mode, electronic
    • gas pressure, flow measurement: pointer type pressure meter or electronic pressure, flow pattern
    • all electronic gas pressure, flow measurement system The single module maximum measuring way: 16 Range: 0 ~ 0.3MPa (pressure); 0 ~ 500sccm (flow) Resolution: 0.01kPa (pressure); 0.01sccm (flow)
    • EPC, EFC work mode: 3kinds:constant current mode, constant voltage mode, bypass mode
    • EPC, EFC working gas: 4kinds:nitrogen, air, hydrogen, helium, argon
    • EPC, EFC L: 4 order EPC, EFC: pressure control range: 0 ~ 0.6MPa; flow rate of 0 ~ 100sccm or 0 ~ 500sccm (air);
    • EPC, EFC control precision pressure 0.01kPa; flow rate: 0.01sccm;
    • external events: 4 road, 4 road; auxiliary control output
    • injector types: packed column sample, the capillary inlet, six valve gas sampling, automatic headspace sampling.
    • detector number: 3 (up); FID, TCD, ECD, FPD and NPD.
    • start sampling: manual, automatic optional
    • communication interface: Ethernet: IEEE802.3

    Insulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization Detector
    Detector technology index
    Hydrogen flame ionization detector (FID)
    •The limit of detection: ≤ 1×10-11g/s (sixteen alkyl);
    • baseline noise: ≤5×10-14A
    • baseline drift: ≤1×10-13A/30min
    • linear range:≥106
    Thermal conductivity detector (TCD)
    • sensitivity: S ≥ 2500mV•ml/mg (sixteen alkyl) (1, 2, 4, 8 times enlarged ,optional.)
    • baseline noise: ≤ 20 μ V
    • baseline drift: ≤ 30 μ V/30min
    • linear range:≥104
    Electron capture detector (ECD)
    •The limit of detection: ≤ 1×10-13g/ml(C 666 - isooctane solution)
    • baseline noise: ≤ 0.03mV
    • baseline drift: ≤ 0.2mV/30min
    • linear range: 103
    • source: 63Ni
    Flame photometric detector (FPD)
    •The limit of detection: (S) ≤5×10-11g/s, (P) ≤1×10-12g/s; methyl parathion - ethanol solution)
    • baseline noise: ≤ 3×10-13A
    • baseline drift: ≤2×10-12A/30min
    • linear range: To sulfur≥102, To P ≥103

    Insulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization DetectorInsulating Oil Gas Analysis Gas Analyzer Gas Chromatograph with Flame Ionization Detector


    Quality 350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)